perplexing one-way problem on Jabsco pumps

First off I haven't been on here in a while. Two kids will do that to your free time I suppose. I had a 95 prostar 190 and upgraded to a 06 X2 a couple of years ago and did one of the first full automatic additional ballast system in the new X2. Two rear bags and a front bow sac using the existing pumps. It's been working great for years. Got about 600 hours on the X2 total (i know, weak, but I ride other's boats a lot.)

Before I go into this puzzling issue, I have been searching the internet, wakeworld and posts on this site for answers and could find nothing even remotely similar. So hopefully this is a worthy post.

My ballast pumps were factory original and over the last two years occasionally one of the pumps would operate in one direction but not the other. Based on speaking with my mechanic if you run it in the direction it works for a minute and then jam the switch in the opposite direction it will work again. I had been doing that when the problem arose and it wasn't a big deal. He said that meant the pump was nearing the end of its life, but it would last a while longer doing that work around.

Over the last couple of months the issue has spread to all of the ballast pumps and it happens every time I take the boat out. I spend 10 minutes trying to get all the pumps to move in the direction i want them to. So I finally decided I would replace all of my pumps.

So I get the new ones in and they work initially but now I am back to all pumps having the same problem. They will operate 1 direction but not the other. Great, it probably wasn't the pumps. So here is all that I tried to determine the source of the problem:

---was I getting the exact same voltage at the connector when i ran it fill or empty. Was I getting enough voltage in general when the pump was on? Yes and yes.
---if i connected the old pumps to another power source (car battery, just touching wires to terminals) do the old pumps work in both directions? yes (great, i just bought three new pumps i dont need.)
---are the pumps upside down? yes (http://www.mastercraft.com/teamtalk/...ghlight=jabsco) however it seems to me that the water getting into the pump due to it being installed upside down would affect it in both directions and mine all work fine in one direction. Plus why would this affect brand new pumps? also the idea that running the pump for 1 minute and jamming it the other way to get it to work would not be consistent with this possible cause. however I may try to flip my kgb pump next weekend and see it it changes since I am struggling to figure this one out. my neighbor thinks running the pump in one direction could clear the leaked water out and then it will run opposite, but I do not think so because it shouldnt run in either direction if there is water in there and also you have to jam the switch into the opposite direction, you cannot just stop and start in the opposite direction after running for 1 minute. but we'll see when i try it.
---do they have green impellors? yes but i dont think that matters. the old ones had green impellors too.
---do timers play a part in this mess? no timers for ballast did not start appearing on mastercrafts until 2007 and my boat is a 2006 (thank goodness)
---is the breaker popped? no and that would be inconsistent with the temporary solution anyway.

So I am now just about out of ideas to try and have come to the mastercraft community for help on fixing this weird issue.

Thanks in advance for anyone that posts any ideas.

Andrew


And finally speaking of ballast, is the new x-star going to have more than the piddly amount of ballast that MC has included over the years or will it step up to the nautique g23 and go ahead and put in all the ballast start from the factory that we all want? i was advised that one solution to my ballast problem was the buy a new boat.....
__________________
Current:
...

Previous Boats:
2006 Mastercraft X2
1995 Mastercraft ProStar 190, New Dimension Tower
1990 Supra Conbrio
http://www.tigerboatdocks.com
Reply With Quote
  #2  
Old 06-20-2012, 04:21 PM
Philscbx's Avatar
Philscbx Philscbx is offline
TT Enthusiast
 
Join Date: May 2011
Boat: 78 S&S, 04 Pro 209
Location: Mn, Minnetonka
Posts: 276
I'll take a stab - It must have relays for forward/reverse.

Has to be a glitch in that area.

Bad Grounds can play havoc.
Reply With Quote
  #3  
Old 06-20-2012, 05:21 PM
c640947's Avatar
c640947 c640947 is offline
TT Enthusiast
 
Join Date: Aug 2004
Boat: temporarily boatless
Location: Houston, TX
Posts: 203
Well would the fact that the connection to the pump gets the proper voltage in forward or reverse rule that out? I mean that fact alone says its a pump issue but I have the same problem with old and new pumps (and they work fine on a car battery) and THAT says its a boat issue. A lot of finger pointing but no smoking gun.

We did consider that the switches at the helm were having issues (do they have relays?) but the fact that the connection get the proper voltage in both directions caused us not to take apart the helm to check out the switches.

(I mean "us" as in me and my neighbor as now I have him sucked into this problem as well.)
__________________
Current:
...

Previous Boats:
2006 Mastercraft X2
1995 Mastercraft ProStar 190, New Dimension Tower
1990 Supra Conbrio
http://www.tigerboatdocks.com
Reply With Quote
  #4  
Old 06-20-2012, 08:31 PM
MattsCraft's Avatar
MattsCraft MattsCraft is offline
MC Devotee
 
Join Date: May 2008
Boat: 2013 X25 - 6.2 Ilmor Baby
Location: Cincinnati, OH
Posts: 1,114
Does not appear to me to be ground if it works in one direction and not the other, if old and new work off a direct connection to a battery, sounds like a switch to me as long as there is no relay inbetween.
Reply With Quote
  #5  
Old 06-20-2012, 08:51 PM
petermegan's Avatar
petermegan petermegan is offline
TT Enthusiast
 
Join Date: Dec 2010
Boat: 2000 Matercraft Prostar 190, LTR330,powerslot,PP,heater
Location: South Australia
Posts: 477
I know nothing of your specific problem, but can you change the wires on the\a pump switching the forward to reverse and see if you get the opposite problem this will tell you whether it is the pump\s. If it isn't try changing the wires at the switches and this will let you know if it is switches or relays\wiring.
Reply With Quote
  #6  
Old 06-20-2012, 09:21 PM
vision's Avatar
vision vision is offline
MC Devotee
 
Join Date: Jun 2006
Boat: 2008 X Star, 2005 X2
Location: Cary NC, Lake Gaston
Posts: 1,071
Your system may have check valves, which are intermittently stuck closed, creating a vacuum and not allowing the tanks to fill or empty. Any blockage to the outflow pathway (depending on how you set up your Fly High set up) will prevent normal filling or emptying.

Do the pumps simply not come on when they are not working, or do the pump motors make noise but no water is moving?
__________________
2008 X star, 2005 X2
Reply With Quote
  #7  
Old 06-21-2012, 07:13 AM
Philscbx's Avatar
Philscbx Philscbx is offline
TT Enthusiast
 
Join Date: May 2011
Boat: 78 S&S, 04 Pro 209
Location: Mn, Minnetonka
Posts: 276
They worked fine on the bench - Forward/Reverse.

If the wires on the back of switch are under 14g -
There must be relays near the pumps - Mine isn't here, or I'd look to confirm.

If in fact there are no relays - this is simply wrong -
and over loads the switch load going double the distance.
It could be simply one wire is loose on the switch - over heated the connection.

If the switch can be popped out of panel -
Then see fried contacts /inside - from loose or burnt connector - Ground.
Connect test light to battery source to confirm Hot/Grounds at the switch.

The pumps would need a good power source for the load they are under,
plus the distance from switch.
Can't imagine done w/o a relay switch pack, with 12 -10g suppling the power near the pump.
Somewhat concerning in a vessel to be allowed to be wired w/o relays.
It would prevent high load damaged leads from starting a fire.

With full power/amps, the pumps would perform as made.
Done wrong - it's like a light bulb on dimmer control half dimmed.
Still surprised circuit breaker didn't see the over load before the switch failed - if true.

I reviewed the links you posted - there was mention in there of ground issues as well.

Usual wire management lacks restraint with wire ties.
If it looks like a monkey food fight of spaghetti under the dash,
it easily leads to these issues, where the slightest snag happens.

I'd like to see that view anyway. I can advise from there.
Restoring aircraft - this is a timely process.


I'd still back trace the pair of wires from pump to a box nearby.
If not found - a call to service to confirm where it isn't .

I don't think check valves apply here,
being the flow has to go both ways in the same port.


Quote:
Well would the fact that the connection to the pump gets the proper voltage in forward or reverse rule that out?
It confirms a hot, but not the ground - depending how the circuit test was connected.
This test also needs to be performed at the switch.


Quote:
Does not appear to me to be ground if it works in one direction and not the other
The ground & hot are switched as pairs - so all it takes is one loose/burnt ground at the switch.
Reply With Quote
  #8  
Old 06-21-2012, 07:39 AM
Thrall's Avatar
Thrall Thrall is offline
MC Maniac
 
Join Date: Jul 2004
Boat: '06 X2 MCX
Location: Eagle River, AK!
Posts: 3,848
Have you done what petermegan said?
If both sets of pumps are doing it, then I'd look at the relays, box under the port back seat. See if it's switching relays corectly.
BTW, you can flip al the pumps on the X2 without even changing any hoses. Rear ones are a little difficult.
__________________
'06 X2 MCX

"I understand why some people may not want to do this the way I have recommended but I can't understand the death grip some people have on a toilet plunger with a hose fitting." -JimN
Reply With Quote
  #9  
Old 06-21-2012, 10:41 AM
Smoothie's Avatar
Smoothie Smoothie is offline
TT Enthusiast
 
Join Date: Dec 2008
Boat: MC XStar 2002 310
Location: Southeast
Posts: 185
@Thrall. How do you flip the pumps? I have heard people running the wires opposite. Black Ground to Red and Red to Black Ground. That way you can flip the pump and it will fill and empty properly according to your switches.
__________________
Evil Conservative
Reply With Quote
  #10  
Old 06-21-2012, 12:01 PM
c640947's Avatar
c640947 c640947 is offline
TT Enthusiast
 
Join Date: Aug 2004
Boat: temporarily boatless
Location: Houston, TX
Posts: 203
OK so I have not simply changed the wires to determine if the pump still doesnt work in the same direction. Will test that.

I will also check out the relay / breaker box under the rear port seat with the information you all gave. I think all the wires go to that and I have not examine that yet. If not problems are found there I will then proceed to the switches at the helm. I will report back on what I find. Hopefully I report back with the solution.

I do not believe it is the check valves (good thought though) as the pump does not turn on. Check valve issue would be pump is on but not moving water i think.

Thanks to everyone for the advice on what to check. I likely won't have much to report until after next weekend since I have family coming into town and I doubt my wife would be happy if I sat in the boat working on pumps while she entertains her in-laws.
__________________
Current:
...

Previous Boats:
2006 Mastercraft X2
1995 Mastercraft ProStar 190, New Dimension Tower
1990 Supra Conbrio
http://www.tigerboatdocks.com
Reply With Quote
Reply

Tags
ballast, direction, jabsco, pumps

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off


All times are GMT -4. The time now is 08:33 AM.