Go Back   TeamTalk > Maintenance Tips, How-tos and Refurbishing Topics > Engine / Drive Train

 
 
Thread Tools Display Modes
Prev Previous Post   Next Post Next
  #1  
Old 06-18-2012, 10:04 AM
Jerseydave's Avatar
Jerseydave Jerseydave is offline
TT Hero
 
Join Date: Jul 2004
Boat: 2005 X-STAR & 1993 Prostar 190 Limited
Location: Jersey
Posts: 5,411
LT-1 still runs cold

On my '93 LT-1 it still runs at 120 degrees. (river temp is 68) Here's what I've done so far.

-Verified the guage works by touching the wire to ground.....guage pins to full temp.
-Replace sending unit for guage
-Replaced both t-stats....143 on bottom, drilled 160 on top
-Replaced steam tube at rear of engine with brass fittings and hoses. I cannot move the steam tube to the front of engine because of my high mounted alternator.

t-stat mixing housing at front of engine feels cold to the touch even after running 25 minutes.
Engine runs fine, no sign of overheating, no warning light or buzzer, no leaks.

I pulled the 160 t-stat to make sure its not stuck open and it's closed.
I have not checked the lower 143 t-stat to see if it's stuck open. Could that be it?
__________________
I was njskier on here.